      人IL-6 ELISA KIT說明書

      更新時間:2011-08-18   點擊次數:2368次

       

      RD
      Human Interleukin 6 (IL-6)

      FOR RESEARCH USE ONLY
      Assay range0.2 pg/ml -8 pg/ml               96determinations
      Purpose
      This kit allows for the determination ofIL-6concentrations in Humanserum, cellculture supernates and other biological fluids
       
      Principle of the assay
      The kit assay Human Interleukin 6(IL-6)level in the sampleuse Purified Human Interleukin 6(IL-6)antibody to coat microtiter plate wells, make solid-phase antibody, then addInterleukin 6(IL-6)to wells,Combined antibody which With HRP labeled goat anti- Human become antibody - antigen - enzyme-antibody complex, after washing Compley,Add TMB substrate solution,TMB substrate becomes blue color At HRP enzyme-catalyzed,reaction is terminated by the addition of a sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450 nm. The concentration of  Human Interleukin 6(IL-6)in the samples is then determined by comparing the O.D. of the samples to the standard curve.
      Materials provided with the kit

      1
      wash solution
      20ml×1bottle
      7
      Stopp Solution
      6ml×1 bottle
      2
      HRP-Conjugate reagent
      6ml×1 bottle
      8
      Standard16pg/ml
      0.5ml×1 bottle
      3
      Microelisa stripplate
      12well×8strips
      9
      Standard diluent
      1.5ml×1bottle
      4
      Sample diluent
      6ml×1 bottle
      10
      Instruction
      1
      5
      Chromogen Solution A
      6ml×1 bottle
      11
      Closure plate membrane
      2
      6
      Chromogen Solution B
      6ml×1 bottle
      12
      Sealed bags
      1

      Specimen requirements
      1.       extractas soon as possible after Specimen collection,and according to the relevant literature, and should be experiment as soon as possible after the extraction. If it can’t, specimen can be kept in -20 ℃ to preserve, Avoid repeated freeze-thaw cycles.
      2.       Can’t detect the sample which contain NaN3, because NaN3 inhibits HRP active.
      Assay procedure
      1.       Dilute and add sample:Dilute Original density Standard as follow table:

      8 pg/ml
      5 Standard
      150μl Original density Standard+150μl Standard diluent
      4pg/ml
      4 Standard
      150μl 5 Standard+150μl Standard diluent
      2 pg/ml
      3 Standard
      150μl 4 Standard+150μl Standard diluent
      1 pg/ml
      2 Standard
      150μl 3 Standard +150μl Standard diluent
      0.5 pg/ml
      1 Standard
      150μl 2 Standard +150μl Standard diluent

      2.add sampleSet blank wells separay (blank comparison wells don’t add sample and HRP-Conjugate reagent, other each step operation is same). testing sample well. add Sample dilution 40μl to testing sample well, then add testing sample 10μl (sample final dilution is 5-fold), add sample to wells , don’t touch the well wall as far as possible, and Gently mix.
      3.Incubate: After closing plate with Closure plate membrane ,incubate for 30 min at 37.
      4.Configurate liquid: 30-fold wash solution diluted 30-fold (or 20-fold) with distilled water and reserve.
      5.washingUncover Closure plate membrane, discardLiquid, dry by swing, add washing buffer to every well, still for 30s then drain,repeat 5 times, dry by pat.
      6.add enzymeAdd HRP-Conjugate reagent 50μl to each well, except  blank well.
      7.incubateOperation with 3.
      8.washingOperation with 5.
      9.colorAdd Chromogen Solution A 50ul and Chromogen Solution B to each well, evade the light preservation for 15 min at 37
      10.Stop the reactionAdd Stop Solution50μl to each well, Stop the reaction(the blue color change to yellow color).
      11.assaytake blank well as zero , Read absorbance at 450nm after Adding Stop Solution and within 15min.
      Steps description

      Standard, Sample diluent

       

      AddStandard, Sample diluent, incubate for 30 min at 37.

       

      Wash 5 time,AddHRP-Conjugate reagent, incubate for 30 min at 37.

       

      Wash 5 times,Add Chromogen Solution A and B, incubate for 30 min at 37.

       

      AddStopp Solution

       

      Read absorbance at 450nm within 15 min

       

      calculate

      Calculate
      Take the standard density as the horizontal, the OD value for the vertical ,draw the standard curve on graph paper, Find out the corresponding density according to the sample OD value by the Sample curve, multiplied by the dilution multiple, or calculate the straight line regression equation of the standard curve with the standard density and the OD value ,with the sample OD value in the equation, calculate the sample density, multiplied by the dilution factor, the result is the sample actual density.
      Important notes
      1.       The kit takes out from the refrigeration environment should be balanced 15-30 minutes in the room temperature, ELISA plates coated if has not use up after opened, the plate should be stored in Sealed bag.
      2.       washing buffer will Crystallization separation, it can be heated the water helps dissolve when dilute . Washing does not affect the result.
      3.       add Sample with sampler Each step, And proofread its accuracy frequently, avoids the experimental error. add sample within 5 min, if the number of sample is much , recommend to use Volley .
      4.       if the testing material content is excessively higher (The sample OD is bigger than the first standard well ),please dilute Sample (n-fold), Please diluenteand multiplied by the dilution factor.×n×5.
      5.       Closure plate membrane only limits the disposable use, to avoid cross-contamination.
      6.       The substrate evade the light preservation.
      7.       Please according to use instruction strictly, The test result determination must take the microtiter plate reader as a standard.
      8.       All samples, washing buffer and each kind of reject should according to infective material process.
      9.       Do not mix reagents with those from other lots.
       
      Storage and validity
      1Storage 2-8℃.
      2validity six months.
       




      主站蜘蛛池模板: 亚洲欧美另类精品久久久| 国产成人一区二区青青草原| 欧美激情视频一区| 雯雯在工地被灌满精在线视频播放| 中文字幕日韩精品人妻| 人妻无码精品| 999re5这里只有精品w| 久久国产成人亚洲精品影院老金| 超碰97人人天天蜜芽| 人妻忍着娇喘被中进中出视频| 2025国产精品| 超级大爆乳奶牛被调教出奶水| 免费人成在线观看视频无码| 日韩精品久久| 91亚洲精品国产自在现线| 插鸡鸡视频| 亚洲av优女天堂熟女| 99国产精品自在自在久久| 二区中文字幕在线观看| 午夜三级成人在线观看 | 亚洲欧美制服| 国产91吞精一区二区三区| 中文字幕肉感巨大的乳专区| 久久婷婷五月综合色和| 日本午夜视频| 色色色综合| 亚洲高潮喷水中文字幕| 性爱视频免费| 亚洲一道一本快点视频| 岛国大片在线免费播放| 久久青草国产精品一区| 男人把女人桶到爽免费应用| 俺也来俺也去俺也射| 亚洲精品入口一区二区乱| 国产高清吃奶成免费视频网站| 第一宅男AV导航| www国产无套内射com| 国产精品一区二区国产| 国产人妻人伦精品1国产| 亚洲欧美日韩成人综合网| 日本欧美一区二区三区乱码|